Panel Constructions shall be nominal4¡± (100mm) thick in manufacturer¡¯s standard and panel width is 4¡¯0¡± (1200 mm) maximum.

All Steel construction panel shall be built with a welded steel frame in which two particle boards of not less than 16mm thick shall be attached. Panel are built with Jack type ceiling/ floor contact devices.

Weight of each panel shall be 4.5 kg per sq. ft. based on panel size
.
 

 

The Superfold Acoustic Seal Wall Systems¡¯ ability to control sound are contributed by its superior sound insulation qualities that help prevent noise pollution. These qualities are:

- the insulated jambs.
- the tubular top seal
- the tongue-in groove astragals
- the drop seal
- the body of the panel
 
 

Sound Seal System - horizontal seal shall be extruded aluminium channel black anodises, non-level floor on overhead supported deflection of 35mm shall be compensated by spring loaded telescopic arms.