Panel Constructions shall be nominal4¡± (100mm) thick
in manufacturer¡¯s standard and panel width is 4¡¯0¡±
(1200 mm) maximum.
All Steel construction panel shall be built with a
welded steel frame in which two particle boards of
not less than 16mm thick shall be attached. Panel
are built with Jack type ceiling/ floor contact devices.
Weight of each panel shall be 4.5 kg per sq. ft. based
on panel size. |
|
|
| |
The Superfold
Acoustic Seal Wall Systems¡¯ ability to control sound
are contributed by its superior sound insulation qualities
that help prevent noise pollution. These qualities are:
- the insulated jambs.
- the tubular top seal
- the tongue-in groove astragals
- the drop seal
- the body of the panel |
|
|
| |
Sound Seal
System - horizontal seal shall be extruded aluminium
channel black anodises, non-level floor on overhead
supported deflection of 35mm shall be compensated by
spring loaded telescopic arms.
|
|
|